This direct-projection safety light curtain for press machines has the highest-level safety based on a design compliant with
international standards, advanced basic performance including enhanced noise resistance and is equipped with a series
connection function and error display function in the event of a problem, making it suitable for a variety of work sites.
Features
-
Failsafe design for the highest level safety
The highest level safety has been realized based on a failsafe design that utilizes mutual checking performed by two CPUs equipped in the receiver, and redundancy of the signal-processing circuit and output circuit.- Complies with international standard IEC61496-1/2 and North
American standard UL61496-1/2. - Complies with China Standard GB4584-2007(some models)
- Complies with international standard IEC61496-1/2 and North
-
Diverse line-up to cope with various operating environments
Select the optimal safety light curtain according to the installation environment, type of press and work content. -
Series connection function and error display function equipped
Flexible installations matched to the operating environment and work content -
Simple to adjust beams
LED indicators equipped: Determine status of main unit with a single glance -
Mutual interference prevention
When multiple RPZ units are installed, a light interference avoidance algorithm (assigned according to the respective wavelengths of light sensors) can prevent mutual interference (up to three sets).
Safety Device Selection Criteria (Protective Range)
- Mechanical press: (Die height + Stroke length) or more
- Hydraulic press: (Full daylight range) or more
* Note that the necessary protective range varies according to the installation conditions. - In the case that the top beam height at the time of installation is 1,400mm or less from the floor surface
→ (Die height + Stroke length + Insufficient length) or more - In the case that the top beam height at the time of installation is more than 1,700mm from the floor surface
→ (Die height + Stroke length – Excess length) or more
* Lowest beam position is assumed to be the top surface of the bolster.
Specifications
RPZ425-□□□X2 | RPZ425-□□□X4 | |
---|---|---|
No. of Beams | 8 ~ 102(Protection Height:140~2020mm) | |
Beam Spacing | 20mm | |
Minimum Object Sensitivity (MOS) | 25mm | |
Detection Distance | 0.2 ~ 4m | 0.2 ~ 7m |
Response Time | ON→OFF: 15ms, OFF→ON: 70ms * When Control Box is connected: ON→OFF: 25ms, OFF→ON: 90ms |
|
Input voltage | 90VAC~240VAC (When control box is used) (Power Supply for Emitter/Receiver only: 24VDC±20%) |
|
Power Consumption | Emitter: 41mA~101mA, Receiver: 41mA~67mA (Control Box: CB6-S: 16.8W, CB6-W: 30W) |
|
Output Contact (CB6) | 2A, 1B Contact Capacity: 250VAC 3A | |
Key Switch Output Contact (CB6) | 1A, 2B Contact Capacity: 220VAC 0.7A (Inductive Load), 1.0A (Resistance Load) | |
Light Source | Infrared LED (wavelength: 870nm) | |
Effective Aperture Angle | Within ± 5° (when detection distance is 3m or more) | Within ± 2.5°(when detection distance is 3m or more) |
External Diagnostic Function | When Test-input line or LA-terminal (in case with Control Box) is: (Vs-3V)~Vs: Emitter OFF, 0~1/2V or open: Emitter ON. * Vs: a voltage value in operating environment. |
|
Ambient Temperature | During operation: -10~55℃ (No freezing), During storage: -30~70℃ | |
Ambient Humidity | During operation: 35~85RH (No freezing), During storage: 35~95RH | |
Ambient Light Intensity | Incandescent light: 3,000lx or less (Light intensity at the receiver surface), Sunlight: 10,000lx or less (Light intensity at the receiver surface) |
|
Insulation Resistance | 20Mohm or more (for 500VDC) | |
Withstand Voltage | 1,000VAC(Sensor), 1,500VAC (Control Box), 50/60Hz, 1min. | |
Degree of Protection | Emitter/Receiver: IP65, Control Box: IP54 (IEC60529) | |
Vibration Resistance | Malfunction Durability: 10~55Hz, Double-amplitude: 0.7㎜,X, Y,Z directions: 20 sweeps | |
Shock Resistance | Malfunction Durability: 100m/s2, {10G}, X,Y, Z directions: 1,000 times | |
Standard Compliance (Sensor only) |
X2-type: IEC61496-1 type-2 ESPE & IEC61496-2 type-2 AOPD IEC61508-1~-7 (SIL1), ISO13849-1: 2006 Cat. 2 PLc X4-type: IEC61496-1 type-4 ESPE & IEC61496-2 type-4 AOPD IEC61508-1~-7 (SIL3), ISO13849-1: 2006 Cat. 4 PLe |